2-Channel DC 5V / 12V Relay Module with Optocoupler

  • RM10.60

  • Ex Tax: RM10.00
  • Product Code: 2 Relay Module Board
  • Availability: In Stock

Available Options

A relay is an electrically operated device. It has a control system and (also called input circuit or input contactor) and controlled system (also called output circuit or output contactor). It is frequently used in an automatic control circuit. To put it simply, it is an automatic switch to controlling a high-current circuit with a low-current signal.

The advantages of a relay lie in its lower inertia of the moving, stability, long-term reliability and small volume. It is widely adopted in devices of power protection, automation technology, sport, remote control, reconnaissance, and communication, as well as in devices of electromechanics and power electronics. Generally speaking, a relay contains an induction part which can reflect input variable like current, voltage, power, resistance, frequency, temperature, pressure, speed and light etc. It also contains an actuator module (output) which can energize or de-energize the connection of controlled circuit. There is an intermediary part between input part and an output part that is used to coupling and isolate input current, as well as actuate the output. When the rated value of the input (voltage, current and temperature etc.) is above the critical value, the controlled output circuit of the relay will be energized or de-energized.

 

Features:

  • Optocoupler isolation
  • Good in safety. In power system and high voltage system, the lower current can control the higher one, able to control various appliances and other equipment with high-current current.
  • Standard interface that can be controlled directly by microcontroller (Arduino, 8051, AVR, PIC, DSP, ARM, ARM, MSP430, TTL logic).
  • Indication LEDs for Relay output status.
  • With a normally-open (NO) and a normally-close (NC) contact.
 

Specification:

  • Number of Relays: 2
  • Control signal: TTL level
  • Rated load: 7A/250VAC; 10A/125VAC; 10A/28VDC;
  • Contact action time: 10ms/5ms
  • Current: 15-20mA per channel

 

Pin definition

clip_image004

  • COM - Common pin: This is source pin, that starts connected to NC, and connects to NO when you apply 0v / GND (active low)
  • NC (Normally Closed): in which case NC is connected with COM when INT1 is set low and disconnected when INT1 is high;
  • NO (Normally Open): in which case NO is disconnected with COM1 when INT1 is set low and connected when INT1 is high.
  • INT 1- Relay 1 control port: changes from the COM–>NO to the COM–>NC when you apply 0v / GND (active low)
  • INT 2- Relay 2 control port: changes from the COM à NO to the COM à NC when you apply 0v / GND (active low)

 

 

Video:

Write a review

Note: HTML is not translated!
    Bad           Good

Related Products

Tags: Relay