Digital Temperature Controller W1401 (DC9-15V)

  • RM35.00

  • Product Code: W1401
  • Availability: In Stock

 

Features

  • High-speed microprocessor, accurate and intelligent to control
  • Automatically switch to cooling or heating mode base on temperature
  • Three display for start, real-time and stop temperature, clear for viewing
  • Indicator working light
  • Power off memory, remember setting after power off
  • Best for control various spatial temperature, water temperature or incubator, etc


Specifications

  • Setting/Measuring Temperature Range: -9 to +99°C
  • Control Accuracy: 1°C
  • Measurement Accuracy: 1°C
  • Refresh Rate: 0.5s
  • Input Power: DC 9 – 15V
  • Output: Relay Output, Capacity 12V 10A
  • Measuring Input: NTC(3950-10K 1%) Waterproof type sensor probe
  • Start Indicator: Red Light
  • Stop Indicator: Green Light
  • Environmemt Requirement: -10 to +60°C
  • Humidity: 20% – 85%
  • PCB Board Size: 78 * 51mm
  • Weight: 52g


Package List

1 * Digital Thermostat with Probe

 

 

Start indicator, LED and buzzer status description:

Start indicator: START (red) light,meaning relay is closed,device start working

Stop lights: STOP (green) light,meaning relay is off,device stop working

Screen:Middle red number means the detected temperature;
Left green number means the set start temperature;
Right green number means the set stop temperature;

Key:

START "▲ ▼" set the start temperature

STOP "▲ ▼" set the stop temperature

 

Operating Instructions

1. High temperature start:
Set the starting temperature value> stop temperature value,
When the detected temperature ≥ start temperature, the relay is closed, refrigeration equipment begin to work;
When the detected temperature ≤ stop temperature, the relay off, refrigeration equipment stops working
For example: Set the starting temperature is 20 ℃, stop temperature is 15 ℃,
When the detected temperature ≥ 20 ℃, the relay is closed, the start Indicator (red) lights;
When the detected temperature value ≤ 15 ℃, the relay off, stop Indicator (green) light.


2. Cold start:
Start temperature set value< stop temperature value,
When the detected temperature ≤ start temperature relay is closed, the heating device operates;
When the detected temperature ≥ stop temperature, the relay off, the heating device is stopped.
For example: Set the starting temperature is 15 ℃, stop temperature is 20 ℃,
When the detected temperature value ≤ 15 ℃, the relay is closed, the start Indicator (red) lights;
When the detected temperature ≥ 20 ℃, the relay off, stop Indicator (green) light.


3. set to start when the temperature value = stop temperature value, the relay off.

 